Encapsulated Transformer 1,2VA 2x6V Velleman
voltage: 2 x 6V
current: 2 x 0.100A
isolation resistance: >5Mohm / 500Vdc
electric strength: >5kV min.
designed for an ambient temperature of max. 40°C
thermal class E, materials to max. 120°
short-circuit protection up to 3VA
possibility of thermal fuse protection
max. temperature for class E: 95°C
primary tension: 230V ± 10%, 50/60Hz
secondary voltage tolerance: +7% - 3% at 230V and max. load
perfect solderability for wave bath
CE labelled
creepage distances and clearances according to IEC742
picture:
- 1*: bobbin with two chambers
- 2*: input winding
- 3*: encapsulation in epoxy resin
- 4*: output winding
- 5*: connection pins
- 6*: polyamide cover
- 7*: magnetic core
- 8*: safety transformer
- 9*: inherently short-circuit proof
- 10*: primary voltage
- 11*: nominal power / temperature
- 12*: manufacturer's reference
- 13*: ordercode
- 14*: meets :
- 15*: nominal secondary voltages
|